NOTE: Please make sure to write down any settings you may need to restore after factory resetting your Node/EdgeCaster
Before performing a factory reset, remove all cables and drives from the Videon device, leaving only Ethernet and power plugged in. If using PoE, remove the Ethernet cable as well.
To perform a factory reset:
- Unplug power from the Videon LiveEdge Node/EdgeCaster device
- Hold down the front button while plugging power back in
- Continue to hold the front button (for about 30-45 seconds) until the front LEDs blink 3-5 times in quick succession
- Release the front button and wait for the device to finish booting
NOTE: Factory Reset will delete ALL recordings that are saved on the internal storage. For software versions > V10.0, it will also delete all created outputs. To create new outputs for device configuration, follow these instructions.